CLIA Kit for Angiopoietin 1 (ANGPT1) - SCA008Hu
CLIA Kit for Angiopoietin 1 (ANGPT1) - SCA008Hu
Couldn't load pickup availability
CLIA Kit for Angiopoietin 1 (ANGPT1)
Sizes: 24T, 48T, 96T
Catalogue Numbers: SCA008Hu-24, SCA008Hu-48, SCA008Hu-96
Lead times: 1-2 weeks, if manufacturer has product in stock
Manufacturer/Ship Location: China
Featured Series Function: Detects protein (regular version)
Method: Chemiluminescence
Test Principle: The microplate provided in this kit has been pre-coated with an antibody specific to Angiopoietin 1 (ANGPT1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Angiopoietin 1 (ANGPT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Angiopoietin 1 (ANGPT1) level in the sample or standard.;
Reactivity: Human
Alternate Names: ANG1, AGP1, AGPT, ANG-I
Target: Angiopoietin 1,
Assay Length: 2h, 40min
Sample Size: 100uL
Sample Type: Serum, Plasma, Tissue Homogenates, Cell Lysates, Other Biological Fluids
Detection Method: Double-antibody Sandwich
Detection Range: 0.55-400ng/mL
Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiopoietin 1 (ANGPT1) were tested 20 times on one plate, respectively.Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiopoietin 1 (ANGPT1) were tested on 3 different plates, 8 replicates in each plate.CV(%) = SD/meanX100
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Assay Procedure: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C; 8. Read RLU value immediately.
Specificity: Reactive with Human ANGPT1 / Angiopoietin 1
Sensitivity: 0.21ng/mL
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Shelf Life: 12 months
Gene ID: 284
UniProt: Q15389
Research Use Only