Low-Temperature High-Speed Microcentrifuge - SLX-1024F
Manufacturer: Servicebio
Price: $13,066.21
Product Description
Maintains low temperature during centrifugation to prevent RNA/protein degradation; automatically stops if imbalance is detected. 4 °C, 15,000 r/min, compatible with 1.5/2 mL × 24, 10 mL × 6, 5 mL × 12.
Catalogue Number: SLX-1024F
Manual available upon request.
Product Introduction
The Low-Temperature High-Speed Microcentrifuge is widely used in fields such as biology, medicine, agriculture, and chemical engineering. It is an instrument that uses centrifugal force to separate specimens by density. It achieves a maximum speed of 15,000 rpm and a maximum relative centrifugal force (RCF) of 20,000 × g. It also ensures no temperature rise during operation, providing optimal protection for specimens.
Product Features
True low temperature, microcentrifuge without heating up
Truly protect samples, reduce RNA/protein degradation, and achieve better experimental results
1. Unsymmetrical balancing monitoring system: if the sample is unsymmetrically placed and unbalanced, the instrument will automatically stop centrifuging.
2. Compatible with various rotors: suitable for 1.5/2mL (standard), 5mL and 10mL centrifuge tubes / blood collection tubes.
Working Environment
|
Power Parameters
|
200-240VAC, 50Hz, 550W; power voltage fluctuation does not exceed 10% of the rated power voltage.
|
|
Room Temperature
|
5℃-40℃
|
|
Relative Humidity
|
Maximum 80%
|
|
Operating Location
|
Indoor use
|
|
Altitude
|
Up to 2000 meters
|
Technical Parameters
|
Dimensions
|
530x355x268mm
|
|
Weight
|
45 kg
|
|
Screen Size
|
5 inches
|
|
Temperature Control Accuracy
|
±2℃
|
|
Operating time
|
1-99 minutes
|
Operation Parameters
|
Operating Mode
|
Continuous
|
|
Time Setting
|
1-99 min
|
|
Balancing Monitoring
|
Gyroscope
|
|
Refrigeration system
|
SECOP Compressor Cooling
|
|
Temperature Range
|
-20℃~40℃
|
|
Temperature Efficiency
|
Specimens at room temperature go in (centrifuge for 10 minutes) and come out at 4℃
|
|
Rotor Capacity
|
[1.5mL / 2mL*24] [5mL*12] [10mL*6]
|
|
Rotor Replacement
|
Quick-change mode: Only requires a dedicated wrench for removal and installation
|
|
Rotor Removal
|
Can be removed as a whole without opening the lid, to prevent the dispersion of specimen gas molecules
|
|
Specimen safety
|
Equipped with multiple sealing rings to prevent dispersion contamination
|
|
Interface Operation
|
Full touch screen interface, can be operated with gloves
|
|
Machine Safety
|
Double lock mechanism, and equipped with manual door opening mechanism during power failure
|
|
Status Indicator
|
LED strip status indicator, displays real-time working status
|
|
Software Functions
|
[Quick cooling setting] [Real-time temperature monitoring] [User program memory (up to 10 sets)] [Real-time parameter adjustment] [Gyroscope balancing detection] [Real-time monitoring of motor overvoltage, undervoltage, blockage, and overheating, with alarms and automatic shutdown]
|
AFSBio Inc. — afsbio.com — Downloaded September 08, 2026
Maintains low temperature during centrifugation to prevent RNA/protein degradation; automatically stops if imbalance is detected. 4 °C, 15,000 r/min, compatible with 1.5/2 mL × 24, 10 mL × 6, 5 mL × 12.
Catalogue Number: SLX-1024F
Manual available upon request.
Product Introduction
The Low-Temperature High-Speed Microcentrifuge is widely used in fields such as biology, medicine, agriculture, and chemical engineering. It is an instrument that uses centrifugal force to separate specimens by density. It achieves a maximum speed of 15,000 rpm and a maximum relative centrifugal force (RCF) of 20,000 × g. It also ensures no temperature rise during operation, providing optimal protection for specimens.
Product Features
True low temperature, microcentrifuge without heating up
Truly protect samples, reduce RNA/protein degradation, and achieve better experimental results
1. Unsymmetrical balancing monitoring system: if the sample is unsymmetrically placed and unbalanced, the instrument will automatically stop centrifuging.
2. Compatible with various rotors: suitable for 1.5/2mL (standard), 5mL and 10mL centrifuge tubes / blood collection tubes.
Working Environment
|
Power Parameters
|
200-240VAC, 50Hz, 550W; power voltage fluctuation does not exceed 10% of the rated power voltage.
|
|
Room Temperature
|
5℃-40℃
|
|
Relative Humidity
|
Maximum 80%
|
|
Operating Location
|
Indoor use
|
|
Altitude
|
Up to 2000 meters
|
Technical Parameters
|
Dimensions
|
530x355x268mm
|
|
Weight
|
45 kg
|
|
Screen Size
|
5 inches
|
|
Temperature Control Accuracy
|
±2℃
|
|
Operating time
|
1-99 minutes
|
Operation Parameters
|
Operating Mode
|
Continuous
|
|
Time Setting
|
1-99 min
|
|
Balancing Monitoring
|
Gyroscope
|
|
Refrigeration system
|
SECOP Compressor Cooling
|
|
Temperature Range
|
-20℃~40℃
|
|
Temperature Efficiency
|
Specimens at room temperature go in (centrifuge for 10 minutes) and come out at 4℃
|
|
Rotor Capacity
|
[1.5mL / 2mL*24] [5mL*12] [10mL*6]
|
|
Rotor Replacement
|
Quick-change mode: Only requires a dedicated wrench for removal and installation
|
|
Rotor Removal
|
Can be removed as a whole without opening the lid, to prevent the dispersion of specimen gas molecules
|
|
Specimen safety
|
Equipped with multiple sealing rings to prevent dispersion contamination
|
|
Interface Operation
|
Full touch screen interface, can be operated with gloves
|
|
Machine Safety
|
Double lock mechanism, and equipped with manual door opening mechanism during power failure
|
|
Status Indicator
|
LED strip status indicator, displays real-time working status
|
|
Software Functions
|
[Quick cooling setting] [Real-time temperature monitoring] [User program memory (up to 10 sets)] [Real-time parameter adjustment] [Gyroscope balancing detection] [Real-time monitoring of motor overvoltage, undervoltage, blockage, and overheating, with alarms and automatic shutdown]
|