CLIA Kit for Free Thyroxine (fT4)
Sizes: 24T, 48T, 96T
Catalogue Numbers: CCA185Ge-24, CCA185Ge-48, CCA185Ge-96
Citations, Manuals and MSDS Available upon request.
Featured Series: Competitive kit
Target: Free Thyroxine
Alternative Names: FTI
Target Species: General species
Featured Series Function: Detects small molecule
Specificity: Reactive with General species fT4 / Free Thyroxine
Method: Chemiluminescence
Detection principle: Competitive Inhibition
Detection
range: 781.25-200,000fg/mL
Sensitivity: 272.41fg/mL
Assay Time: 2h
Sample Size: 50uL
Recommended/Predicted
Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Free Thyroxine (fT4).
No significant cross-reactivity or interference between Free Thyroxine (fT4) and analogues was observed.
Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Free Thyroxine (fT4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Free Thyroxine (fT4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Target: 1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Test principle: The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Free Thyroxine (fT4). A competitive inhibition reaction is launched between biotin labeled Free Thyroxine (fT4) and unlabeled Free Thyroxine (fT4) (Standards or samples) with the pre-coated antibody specific to Free Thyroxine (fT4). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Free Thyroxine (fT4) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Free Thyroxine (fT4) level in the sample or standard.