CLIA Kit for Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF)
Sizes: 24T, 48T, 96T
Catalogue Numbers: SCB479Mu-24, SCB479Mu-48, SCB479Mu-96
Citations, Manuals and MSDS Available upon request.
Featured Series: Sandwich kit
Target: Heparin Binding Epidermal Growth Factor Like Growth Factor
Alternative Names: HB-EGF; DTR; DTS; DTSF; HEGFL; Diphtheria Toxin Receptor; Proheparin-binding EGF-like growth factor; Diphtheria toxin receptor
Target Species: Mouse
Uniprot: Q06186
Gene ID: 15200
Featured Series Function: Detects protein (regular version)
Specificity: Reactive with Mouse HBEGF / Heparin Binding Epidermal Growth Factor Like Growth Factor
Method: Chemiluminescence
Detection principle: Double-antibody Sandwich
Detection
range: 1.37-1,000pg/mL
Sensitivity: 0.53pg/mL
Assay Time: 2h, 40min
Sample Size: 100uL
Recommended/Predicted
Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF).
No significant cross-reactivity or interference between Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF) and analogues was observed.
Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Target: 1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Heparin Binding Epidermal Growth Factor Like Growth Factor (HBEGF) level in the sample or standard.;
Research Area: Cytokine; Tumor immunity; Infection immunity;
Research Use Only