CLIA Kit for Inhibin Alpha (INHa)
Size: 96T
Catalogue Number: UCCA395Mu-96
Citations, Manuals and MSDS Available upon request.
Target: Inhibin Alpha (INHa)
Alternative Names: INH-A
Target Species: Mouse
Detection range: 12.35-1,000pg/mL
Sensitivity: 5.11pg/mL
Uniprot: Q04997
Gene ID: 16322
Featured Series Function: Detects small molecule
Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids
Assay Time: 2h
Method: Chemiluminescence
Specificity: Reactive with Mouse INHa / Inhibin Alpha
Detection principle: Competitive Inhibition
Sample Size: 50uL
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Inhibin Alpha (INHa).
No significant cross-reactivity or interference between Inhibin Alpha (INHa) and analogues was observed.
Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibin Alpha (INHa) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibin Alpha (INHa) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary: 1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Test principle: The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Inhibin Alpha (INHa). A competitive inhibition reaction is launched between biotin labeled Inhibin Alpha (INHa) and unlabeled Inhibin Alpha (INHa) (Standards or samples) with the pre-coated antibody specific to Inhibin Alpha (INHa). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Inhibin Alpha (INHa) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Inhibin Alpha (INHa) level in the sample or standard.
Research Area: Endocrinology; Reproductive science; Hormone metabolism;