WE DO NOT SHIP TO RESIDENTIAL ADDRESSES. For pricing in CAD/AUD/NZD please contact us.

CLIA Kit for Myeloid Progenitor Inhibitory Factor 2 (MPIF2) - SCA695Hu

CLIA Kit for Myeloid Progenitor Inhibitory Factor 2 (MPIF2) - SCA695Hu

Regular price
$470.40
Regular price
Sale price
$470.40
Unit price
per 
Availability
Sold out

CLIA Kit for Myeloid Progenitor Inhibitory Factor 2 (MPIF2)

Sizes: 24T, 48T, 96T

Catalogue Numbers: SCA695Hu-24, SCA695Hu-48, SCA695Hu-96

Citations, Manuals and MSDS Available upon request.

Featured Series: Sandwich kit

Target: Myeloid Progenitor Inhibitory Factor 2

Alternative Names: CCL24; SCYA24; Ckb-6; Eotaxin-2; Chemokine C-C-Motif Ligand 24; Eosinophil chemotactic protein 2; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 24

Target Species: Human

Uniprot: O00175

Gene ID: 6369

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human MPIF2 / Myeloid Progenitor Inhibitory Factor 2

Method: Chemiluminescence

Detection principle: Double-antibody Sandwich

Detection
range: 13.7-10,000pg/mL

Sensitivity: 5.1pg/mL

Assay Time: 2h, 40min

Sample Size: 100uL

Recommended/Predicted
Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Myeloid Progenitor Inhibitory Factor 2 (MPIF2).
No significant cross-reactivity or interference between Myeloid Progenitor Inhibitory Factor 2 (MPIF2) and analogues was observed.

Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myeloid Progenitor Inhibitory Factor 2 (MPIF2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myeloid Progenitor Inhibitory Factor 2 (MPIF2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Target: 1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Myeloid Progenitor Inhibitory Factor 2 (MPIF2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Myeloid Progenitor Inhibitory Factor 2 (MPIF2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Myeloid Progenitor Inhibitory Factor 2 (MPIF2) level in the sample or standard.;

Research Area: Cytokine; Infection immunity;

Research Use Only