WE DO NOT SHIP TO RESIDENTIAL ADDRESSES. For pricing in CAD/AUD/NZD please contact us.

CLIA Kit for Plasminogen Activator Inhibitor 2 (PAI2) - SCA531Hu

CLIA Kit for Plasminogen Activator Inhibitor 2 (PAI2) - SCA531Hu

Regular price
$470.40
Regular price
Sale price
$470.40
Unit price
per 
Availability
Sold out

CLIA Kit for Plasminogen Activator Inhibitor 2 (PAI2)

Sizes: 24T, 48T, 96T

Catalogue Numbers: SCA531Hu-24, SCA531Hu-48, SCA531Hu-96

Citations, Manuals and MSDS Available upon request.

Featured Series: Sandwich kit

Target: Plasminogen Activator Inhibitor 2

Alternative Names: SERPINB2; PLANH2; Serpin Peptidase Inhibitor Clade B Member 2; Monocyte Arg-serpin; Placental plasminogen activator inhibitor; Serpin B2; Urokinase inhibitor

Target Species: Human

Uniprot: P05120

Gene ID: 5055

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Human PAI2 / Plasminogen Activator Inhibitor 2

Method: Chemiluminescence

Detection principle: Double-antibody Sandwich

Detection
range: 2.74-2,000pg/mL

Sensitivity: 1.27pg/mL

Assay Time: 2h, 40min

Sample Size: 100uL

Recommended/Predicted
Sample Types: Plasma

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Plasminogen Activator Inhibitor 2 (PAI2).
No significant cross-reactivity or interference between Plasminogen Activator Inhibitor 2 (PAI2) and analogues was observed.

Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Plasminogen Activator Inhibitor 2 (PAI2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Plasminogen Activator Inhibitor 2 (PAI2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Target: 1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Plasminogen Activator Inhibitor 2 (PAI2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Plasminogen Activator Inhibitor 2 (PAI2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Plasminogen Activator Inhibitor 2 (PAI2) level in the sample or standard.;

Research Area: Hematology; Reproductive science;

Research Use Only