CLIA Kit for Troponin T Type 2, Cardiac (TNNT2)
Sizes: 24T, 48T, 96T
Catalogue Numbers: SCD232Ra-24, SCD232Ra-48, SCD232Ra-96
Citations, Manuals and MSDS Available upon request.
Featured Series: Sandwich kit
Target: Troponin T Type 2, Cardiac
Alternative Names: CMH2; cTnT; TnTc; Cardiomyopathy, Hypertrophic 2; Cardiac muscle troponin T
Target Species: Rat
Uniprot: P50753
Gene ID: 24837
Featured Series Function: Detects protein (regular version)
Specificity: Reactive with Rat TNNT2 / Troponin T Type 2, Cardiac
Method: Chemiluminescence
Detection principle: Double-antibody Sandwich
Detection
range: 4.1-3,000pg/mL
Sensitivity: 1.6pg/mL
Assay Time: 2h, 40min
Sample Size: 100uL
Recommended/Predicted
Sample Types: Serum, Plasma and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of Troponin T Type 2, Cardiac (TNNT2).
No significant cross-reactivity or interference between Troponin T Type 2, Cardiac (TNNT2) and analogues was observed.
Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin T Type 2, Cardiac (TNNT2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin T Type 2, Cardiac (TNNT2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Target: 1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Troponin T Type 2, Cardiac (TNNT2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Troponin T Type 2, Cardiac (TNNT2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Troponin T Type 2, Cardiac (TNNT2) level in the sample or standard.;
Research Area: Cardiovascular biology;
Research Use Only