WE DO NOT SHIP TO RESIDENTIAL ADDRESSES. For pricing in CAD/AUD/NZD please contact us.

CLIA Kit for Vascular Endothelial Growth Factor Receptor 1 (VEGFR1) - SCB818Mu

CLIA Kit for Vascular Endothelial Growth Factor Receptor 1 (VEGFR1) - SCB818Mu

Regular price
$484.40
Regular price
Sale price
$484.40
Unit price
per 
Availability
Sold out

CLIA Kit for Vascular Endothelial Growth Factor Receptor 1 (VEGFR1)

Sizes: 24T, 48T, 96T

Catalogue Numbers: SCB818Mu-24, SCB818Mu-48, SCB818Mu-96

Citations, Manuals and MSDS Available upon request.

Featured Series: Sandwich kit

Target: Vascular Endothelial Growth Factor Receptor 1

Alternative Names: Flt1; Fms-Related Tyrosine Kinase 1; Vascular Permeability Factor Receptor; Fms-like tyrosine kinase 1; Tyrosine-protein kinase receptor FLT

Target Species: Mouse

Uniprot: P35969

Gene ID: 14254

Featured Series Function: Detects protein (regular version)

Specificity: Reactive with Mouse VEGFR1 / Vascular Endothelial Growth Factor Receptor 1

Method: Chemiluminescence

Detection principle: Double-antibody Sandwich

Detection
range: 27.4-20,000pg/mL

Sensitivity: 9.9pg/mL

Assay Time: 2h, 40min

Sample Size: 100uL

Recommended/Predicted
Sample Types: Serum, Plasma, Tissue Homogenates and other Biological Fluids

Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%

Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)

Shelf-life: 12 months

Specificity: This assay has high sensitivity and excellent specificity for detection of Vascular Endothelial Growth Factor Receptor 1 (VEGFR1).
No significant cross-reactivity or interference between Vascular Endothelial Growth Factor Receptor 1 (VEGFR1) and analogues was observed.

Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vascular Endothelial Growth Factor Receptor 1 (VEGFR1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vascular Endothelial Growth Factor Receptor 1 (VEGFR1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Target: 1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Vascular Endothelial Growth Factor Receptor 1 (VEGFR1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Vascular Endothelial Growth Factor Receptor 1 (VEGFR1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Vascular Endothelial Growth Factor Receptor 1 (VEGFR1) level in the sample or standard.;

Research Area: Signal transduction; Tumor immunity;

Research Use Only