CLIA Kit for VEGF Co Regulated Chemokine 1 (VCC1)
Sizes: 24T, 48T, 96T
Catalogue Numbers: SCC068Ra-24, SCC068Ra-48, SCC068Ra-96
Citations, Manuals and MSDS Available upon request.
Featured Series: Sandwich kit
Target: VEGF Co Regulated Chemokine 1
Alternative Names: CXCL17; SCYB17; DMC; Chemokine C-X-C-Motif Ligand 7; Dendritic cell and monocyte chemokine-like protein
Target Species: Rat
Uniprot: D4A875
Gene ID: 308436
Featured Series Function: Detects protein (regular version)
Specificity: Reactive with Rat VCC1 / VEGF Co Regulated Chemokine 1
Method: Chemiluminescence
Detection principle: Double-antibody Sandwich
Detection
range: 1.37-1,000pg/mL
Sensitivity: 0.57pg/mL
Assay Time: 2h, 40min
Sample Size: 100uL
Recommended/Predicted
Sample Types: Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates and other Biological Fluids
Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12%
Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life)
Shelf-life: 12 months
Specificity: This assay has high sensitivity and excellent specificity for detection of VEGF Co Regulated Chemokine 1 (VCC1).
No significant cross-reactivity or interference between VEGF Co Regulated Chemokine 1 (VCC1) and analogues was observed.
Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level VEGF Co Regulated Chemokine 1 (VCC1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level VEGF Co Regulated Chemokine 1 (VCC1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Target: 1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to VEGF Co Regulated Chemokine 1 (VCC1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to VEGF Co Regulated Chemokine 1 (VCC1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the VEGF Co Regulated Chemokine 1 (VCC1) level in the sample or standard.;
Research Area: Cytokine; Tumor immunity; Infection immunity;
Research Use Only