WE DO NOT SHIP TO RESIDENTIAL ADDRESSES. For pricing in CAD/AUD/NZD please contact us.

Multiplex Assay Kit for Coiled Coil And C2 Domain Containing Protein 1A (CC2D1A), etc. by FLIA (Flow Luminescence Immunoassay) - LML275Hu

Multiplex Assay Kit for Coiled Coil And C2 Domain Containing Protein 1A (CC2D1A), etc. by FLIA (Flow Luminescence Immunoassay) - LML275Hu

Regular price
$1,293.60
Regular price
Sale price
$1,293.60
Unit price
per 
Availability
Sold out

Multiplex Assay Kit for Coiled Coil And C2 Domain Containing Protein 1A (CC2D1A), etc. by FLIA (Flow Luminescence Immunoassay)

Size: 96T

Catalogue Number: LML275Hu-96

Citations, Manuals and MSDS Available upon request.

Detection range: 0.02-20ng/mL

Application: FLIA Kit for Antigen Detection.

Organism species: Homo sapiens (Human)

Sensitivity: The minimum detectable dose of this kit is typically less than 0.007 ng/mL

Sample type: Tissue homogenates and other biological fluids.

Assay length: 3h

Method: Double-antibody Sandwich

Specificity: This assay has high sensitivity and excellent specificity for detection of Coiled Coil And C2 Domain Containing Protein 1A (CC2D1A), etc. by FLIA (Flow Luminescence Immunoassay).No significant cross-reactivity or interference between Coiled Coil And C2 Domain Containing Protein 1A (CC2D1A), etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Coiled Coil And C2 Domain Containing Protein 1A (CC2D1A), etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Coiled Coil And C2 Domain Containing Protein 1A (CC2D1A), etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%

Assay procedure summary: 1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle: Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed isproportional to the concentration of analytes of interest in the sample.

Alternative Names: FREUD-1; MRT3; AKI1; Mental Retardation, Nonsyndromic, Autosomal Recessive 3; Five prime repressor element under dual repression-binding 1; Akt kinase-interacting protein 1

Item Name: Coiled Coil And C2 Domain Containing Protein 1A

Research Field: Signal transduction;

Uniprot: Q6P1N0

Research Use Only