Low-Temperature High-Speed Microcentrifuge - SLX-1024F
Low-Temperature High-Speed Microcentrifuge - SLX-1024F
Low-Temperature High-Speed Microcentrifuge - SLX-1024F

Low-Temperature High-Speed Microcentrifuge - SLX-1024F

Regular price
$13,066.21
Regular price
Sale price
$13,066.21
Unit price
per 
Availability
Sold out

Maintains low temperature during centrifugation to prevent RNA/protein degradation; automatically stops if imbalance is detected. 4 °C, 15,000 r/min, compatible with 1.5/2 mL × 24, 10 mL × 6, 5 mL × 12.

Catalogue Number: SLX-1024F

Manual available upon request.

Product Introduction

The Low-Temperature High-Speed Microcentrifuge is widely used in fields such as biology, medicine, agriculture, and chemical engineering. It is an instrument that uses centrifugal force to separate specimens by density. It achieves a maximum speed of 15,000 rpm and a maximum relative centrifugal force (RCF) of 20,000 × g. It also ensures no temperature rise during operation, providing optimal protection for specimens.


Product Features

True low temperature, microcentrifuge without heating up

Truly protect samples, reduce RNA/protein degradation, and achieve better experimental results

1. Unsymmetrical balancing monitoring system: if the sample is unsymmetrically placed and unbalanced, the instrument will automatically stop centrifuging.

2. Compatible with various rotors: suitable for 1.5/2mL (standard), 5mL and 10mL centrifuge tubes / blood collection tubes.


Working Environment

Power Parameters

200-240VAC, 50Hz, 550W; power voltage fluctuation does not exceed 10% of the rated power voltage.

Room Temperature

5℃-40℃

Relative Humidity

Maximum 80%

Operating Location

Indoor use

Altitude

Up to 2000 meters

Technical Parameters

Dimensions

530x355x268mm

Weight

45 kg

Screen Size

5 inches

Temperature Control Accuracy

±2℃

Operating time

1-99 minutes

Operation Parameters

Operating Mode

Continuous

Time Setting

1-99 min

Balancing Monitoring

Gyroscope

Refrigeration system

SECOP Compressor Cooling 

Temperature Range

-20℃~40℃

Temperature Efficiency

Specimens at room temperature go in (centrifuge for 10 minutes) and come out at 4℃

Rotor Capacity

[1.5mL / 2mL*24] [5mL*12] [10mL*6]

Rotor Replacement

Quick-change mode: Only requires a dedicated wrench for removal and installation

Rotor Removal

Can be removed as a whole without opening the lid, to prevent the dispersion of specimen gas molecules

Specimen safety

Equipped with multiple sealing rings to prevent dispersion contamination

Interface Operation

Full touch screen interface, can be operated with gloves

Machine Safety

Double lock mechanism, and equipped with manual door opening mechanism during power failure

Status Indicator

LED strip status indicator, displays real-time working status

Software Functions

[Quick cooling setting] [Real-time temperature monitoring] [User program memory (up to 10 sets)] [Real-time parameter adjustment] [Gyroscope balancing detection] [Real-time monitoring of motor overvoltage, undervoltage, blockage, and overheating, with alarms and automatic shutdown]