WE DO NOT SHIP TO RESIDENTIAL ADDRESSES. For pricing in CAD/AUD/NZD please contact us.

ELISA Kit for Breast Cancer Anti-Estrogen Resistance 1 (BCAR1) - SEG769Hu

ELISA Kit for Breast Cancer Anti-Estrogen Resistance 1 (BCAR1) - SEG769Hu

Regular price
$392.00
Regular price
Sale price
$392.00
Unit price
per 
Availability
Sold out

ELISA Kit for Breast Cancer Anti-Estrogen Resistance 1 (BCAR1) Sizes: 24T, 48T, 96T Catalogue Numbers: SEG769Hu-24, SEG769Hu-48, SEG769Hu-96 Citations, Manuals and MSDS Available upon request. Featured Series: Sandwich kit Target: Breast Cancer Anti-Estrogen Resistance 1 Alternative Names: CAS; CRKAS; P130Cas; CASS1; Crk-Associated Substrate; Cas Scaffolding Protein Family Member 1 Target Species: Human Uniprot: P56945 Gene ID: 9564 Featured Series Function: Detects protein (regular version) Specificity: Reactive with Human BCAR1 / Breast Cancer Anti-Estrogen Resistance 1 Method: Colormetric Detection principle: Double-antibody Sandwich Detection range: 78.12-5000pg/mL Sensitivity: 27pg/mL Assay Time: 3h Sample Size: 100uL Recommended/Predicted Sample Types: Serum, Plasma, Tissue Homogenates and other Biological Fluids Assay Precision: Intra-Assay: CV<10%, Inter-Assay: CV<12% Storage: 4°C for 1 month/ -20°C for long-term(One year within shelf life) Shelf-life: 12 months Specificity: This assay has high sensitivity and excellent specificity for detection of Breast Cancer Anti-Estrogen Resistance 1 (BCAR1). No significant cross-reactivity or interference between Breast Cancer Anti-Estrogen Resistance 1 (BCAR1) and analogues was observed. Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Breast Cancer Anti-Estrogen Resistance 1 (BCAR1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Breast Cancer Anti-Estrogen Resistance 1 (BCAR1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. Target: 1. Prepare all reagents, samples and standards; 2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C; 3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50µL Stop Solution. Read at 450nm immediately. Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Breast Cancer Anti-Estrogen Resistance 1 (BCAR1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Breast Cancer Anti-Estrogen Resistance 1 (BCAR1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Breast Cancer Anti-Estrogen Resistance 1 (BCAR1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Breast Cancer Anti-Estrogen Resistance 1 (BCAR1) in the samples is then determined by comparing the O.D. of the samples to the standard curve. Research Area: Tumor immunity; Research Use Only